Phmsa Triskelion Logo United States Department of Transportation

Digital Imaging of Pipeline Mechanical Damage and Residual Stress

Overview

Fast Facts

Project No. 292
Contract No. DTRT57-09-C-10046
Research Award Recipient JENTEK Sensors Inc. 121 Bartlett Street Marlborough, MA 01752
AOTR James Merritt
Researcher Contact Info JENTEK Sensors, Inc. 110-1 Clematis Avenue Waltham, MA 02453-7013 Phone: (781) 642-9666 Fax: (781) 642-7525 Neil Goldfine, President JENTEK Sensors, Inc. [jentek@shore.net]

Financial and Status Data

Project Status Closed
Start Fiscal Year 2009 (08/14/2009)
End Fiscal Year 2010 (02/13/2010)
PHMSA $$ Budgeted $99,975.00

Main Objective

This project addresses the need for a more reliable means of characterizing pipeline mechanical damage through application of digital eddy current imaging. JENTEK's patented Meandering Winding Magnetometer (MWM) arrays have demonstrated capability to use lift-off measurements to profile the surface of a dented area, while MWM-Array measured magnetic permeability can be correlated with residual stresses around and within the mechanical damage site.

Successful completion of this program will result in enhanced remaining life prediction capability for pipelines suffering mechanical damage and a reliable decision support tool for pipeline owners and operators. This will enable operators to avoid overly conservative decisions while enhancing pipeline safety.

Public Abstract

While mechanical damage to pipelines is a common occurrence, the impact of mechanical damage on pipeline remaining life is not easily determined. The mechanical damage features, such as residual stresses and stress concentrations, will determine the effect of the damage on pipeline remaining life. Empirical relationships between damage features and burst pressure have been developed and adopted into national and international standards, but they are conservative to encompass the scatter in the data.

Mechanical damage characterization and assessment have been highlighted as a critical need by PHMSA, PRCI and at public forums. Yet no "low-cost, time-efficient, reliable and simple to use" solution is available. We will deliver such a low cost, easy to use solution in the form of both a hand held version and a portable version, based on our award winning MWM-Array technology.

Relevant Files & Links

Final Report

Final report on Digital Imaging of Pipeline Mechanical Damage and Residual Stress, by JENTEK Sensors

DOT_Contract_DTRT57-09-C-10046_pipeline_mechanical_damage_final__report.pdf

Other Files

Technical Brief September 2009

Technical_brief_on_DTRT57-09-C-10046.pdf