PHMSA Gas Transmission (GT) Integrity Management
Time: 04/23/2014 07:30 PM

Rule Section: §192.917(e)(4)

ERW pipe.

Rule Hierarchy:

Rule Language:

If a covered pipeline segment contains low frequency electric resistance welded pipe (ERW), lap welded pipe or other pipe that satisfies the conditions specified in ASME/ANSI B31.8 S, Appendices A4.3 and A4.4, and any covered or non covered segment in the pipeline system with such pipe has experienced seam failure, or operating pressure on the covered segment has increased over the maximum operating pressure experienced during the preceding five years, an operator must select an assessment technology or technologies with a proven application capable of assessing seam integrity and seam corrosion anomalies. The operator must prioritize the covered segment as a high risk segment for the baseline assessment or a subsequent reassessment.

Related Topics:

Related Protocol Questions: