PHMSA Gas Transmission (GT) Integrity Management
Time: 05/22/2013 08:00 PM

Protocol Area H. Preventive and Mitigative Measures

Protocol:
 A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P 

H.01 General Requirements (Identification of Additional Measures)

Verify that a process is in place to identify additional measures to prevent a pipeline failure and to mitigate the consequences of a pipeline failure in a high consequence area. [§192.935(a)]

[See Details...]

H.02 Third Party Damage

Verify that the following preventive and mitigative requirements regarding threats due to third party damage have been addressed: [§192.935(b)(1) and §192.935(e)]

[See Details...]

H.03 Pipelines Operating Below 30% SMYS

Verify that the following preventive and mitigative requirements for pipelines operating below 30% SMYS have been addressed: [§192.935(d)]

[See Details...]

H.04 Plastic Transmission Pipeline

For plastic transmission pipelines, verify that applicable third party damage requirements have been applied to covered segments of the pipeline. [§192.935(e)]

[See Details...]

H.05 Outside Force Damage

Verify that the operator adequately addresses threats due to outside force (e.g., earth movement, floods, unstable suspension bridge). [§192.935(b)(2)]

[See Details...]

H.06 Corrosion

Verify that the operator takes required actions to address corrosion threats. [§192.917(e)(5)]

[See Details...]

H.07 Automatic Shut-Off Valves or Remote Control Valves

Verify that the operator has a process to decide if automatic shut-off valves or remote control valves represent an efficient means of adding protection to potentially affected high consequence areas. [§192.935(c)]

[See Details...]

H.08 General Requirements (Implementation of Additional Measures)

Verify that the operator has identified and implemented (or scheduled) additional measures beyond those already required by Part 192 to prevent a pipeline failure and to mitigate the consequences of a pipeline failure in a high consequence area: [§192.935(a)]

[See Details...]

Explanation of Protocol Format

Each protocol element will have top-tier protocols that address the high level requirements. The regulatory requirement upon which the protocol is based is contained in brackets; e.g., [§192.905(a)]

Each top-tier protocol will have detailed "sub-tier" protocols which collectively lead the inspector to draw overall conclusions about compliance with the top-tier protocol. The regulatory requirement, upon which each sub-tier protocol is based, is also contained in brackets.

Notes on protocols:
Protocol:
 A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P 
PHMSA Home | Pipeline Safety Website | Feedback | Privacy Policy | FOIA