Rule Section: §192.941(b)(2)

Unprotected Pipe or Cathodically Protected Pipe Where Electrical Surveys are Impractical.

Rule Hierarchy:

Rule Language:

Unprotected Pipe or Cathodically Protected Pipe Where Electrical Surveys are Impractical. If an electrical survey is impractical on the covered segment an operator must -

  1. Conduct leakage surveys as required by 192.706 at 4-month intervals; and
  2. Every 18 months, identify and remediate areas of active corrosion by evaluating leak repair and inspection records, corrosion monitoring records, exposed pipe inspection records, and the pipeline environment.