Unprotected Pipe or Cathodically Protected Pipe Where Electrical Surveys are Impractical.
Rule Hierarchy:
- 192.941
What is a low stress reassessment?
- 192.941(b)
External Corrosion.
- 192.941(b)(2) Unprotected Pipe or Cathodically Protected Pipe Where Electrical Surveys are Impractical.
Rule Language:
Unprotected Pipe or Cathodically Protected Pipe Where Electrical Surveys are Impractical. If an electrical survey is impractical on the covered segment an operator must -
- Conduct leakage surveys as required by §192.706 at 4-month intervals; and
- Every 18 months, identify and remediate areas of active corrosion by evaluating leak repair and inspection records, corrosion monitoring records, exposed pipe inspection records, and the pipeline environment.