If the operator elects to use ICDA to assess a covered segment operating with electrolyte present in the gas stream (wet gas), verify that the operator develops and implements an ICDA plan in accordance with §192.927 which addresses the following. [§192.927(b)]
Verify that the operator developed a documented ICDA plan which demonstrates how the operator will conduct ICDA on the entire pipeline in which covered segments are present to effectively address internal corrosion. [§192.927(c)]
Verify the operator has provided notification to PHMSA, and applicable state or local safety authorities, of an ICDA wet gas "other technology" application in accordance with �192.921 (a) (4) or �192.937 (c) (4). [�192.927(b)]