Question: Does the rule apply to more than line pipe?

Answer: Yes. The continual evaluation, preventive and mitigative actions, and information analysis requirements of the rule apply to pipelines as defined in 49 CFR 192.3. This includes, but is not limited to, line pipe, valves and other appurtenances attached to line pipe, compressor units, metering stations, regulator stations, delivery stations, holders, and fabricated assemblies. The baseline integrity assessment and periodic re-assessment requirements apply only to line pipe including crossovers, bypass piping, etc.

These Frequently Asked Questions (FAQs) are intended to clarify, explain, and promote better understanding of the pipeline integrity management rules. These FAQs are not substantive rules and do not create rights, assign duties, or impose new obligations not outlined in the existing integrity management regulations and standards. Requests for informal interpretations regarding the applicability of one or more of the pipeline integrity management rules to a specific situation may be submitted to PHMSA in accordance with 49 C.F.R. § 190.11.
PHMSA Home | Pipeline Safety Website | Feedback | Privacy Policy | FOIA