Question: Filled, Shorted, and an Incomplete Inspection: If an operator performs Guided Wave Ultrasonic Testing (GWUT) on a shorted and filled cased pipe, but is unable to clear the short and does not get 100% coverage with the GWUT inspection, has the operator satisfied the assessment requirements?
Answer: No. Because the entire carrier pipe has not been assessed, the assessment requirements have not been fulfilled in accordance with DOT regulations. If the short is not cleared, this is a high risk cased crossing and would need to be excavated and directly examined.